Hoag Memorial Hospital
Hoag Drive: a permanent tied-back soldier pile wall for the hospital central plant site.
Newport Beach, California
Hoag Hospital’s central plant site sits at the base of a campus hill above Pacific Coast Highway. It required a permanent retaining wall about 50 feet high.
Cefali & Associates designed a tied-back soldier pile wall for the site. Groundwater, a nearby property line, an existing methane gas well, and seismic loading all shaped the design.
Local conditions
The permanent wall used 47 soldier piles and 70 tiebacks. The nearby Newport-Inglewood fault added a seismic load increment, while property limits constrained permanent anchors.
Engineering services
Explore the services used on documented local projects and the broader engineering work available for other site conditions.
Published work

Hoag Drive: a permanent tied-back soldier pile wall for the hospital central plant site.